Megaflow® AW HVI Hydraulic Oil

# LBPH814633

High VI Anti-Wear Hydraulic Oil for Wide Temperature Ranges

Phillips 66® Megaflow AW HVI Hydraulic Oil is a high-quality, high viscosity index anti-wear hydraulic oil developed for use in industrial and mobile equipment operating in cold climates or in locations subject to wide variations in ambient temperatures. It meets the performance requirements of all major hydraulic pump manufacturers, and is recommended for use in all types of high-pressure, high-speed hydraulic pumps. It is particularly recommended for year-round use in mobile equipment such as bucket trucks, cranes and aerial lifts.

Features & Benefits

  • Excellent service over a wide temperature range
  • Excellent wear protection for hydraulic pumps and motors
  • Excellent oxidation resistance and thermal stability
  • Protects against rust and corrosion
  • Excellent water-separating properties
  • Good foam resistance
  • Excellent low-temperature properties for cold start-ups
  • High dielectric strength for use in electrical service bucket trucks (cherry pickers)

Applications

  • Industrial and mobile equipment operating in cold weather or in locations subject to wide temperature fluctuations
  • Bucket trucks (cherry pickers) used for servicing electrical power lines or for tree-trimming
  • Hydraulic hoists and service station lifts
  • Marine cargo winches and steering systems
  • Off-road construction, mining and marine equipment
  • Chain drives
  • Electric motor bearings
Licenses & Approvals

Megaflow AW Hydraulic Oil meets the requirements of the following industry and OEM specifications:

  • DIN 51524 Part 3, Antiwear Hydraulic Oils, Type HVLP
  • Eaton-Vickers I-286-S, M-2950-S
  • ISO 11158:1997, Family H (Hydraulic Systems), Type HV
  • Parker Hannifin (Denison) HF-0, HF-1, HF-2

Additional Details

ISO Grade 15
Specific Gravity @ 60°F 0.857
Density, lbs/gal @ 60°F 7.14
Color, ASTM D1500 0.5
Flash Point (COC), °C (°F) 181 (358)
Pour Point, °C (°F) -61 (-78)
Viscosity
cSt @ 40°C 15
cSt @ 100°C 3.8
SUS @ 100°F 77.5
SUS @ 210°F 37.5
Viscosity Index 151
Acid Number, ASTM D974, mg KOH/g 0.38
Copper Corrosion, ASTM D130 1a
Demulsibility, ASTM D1401, minutes to pass 15
Dielectric Strength, ASTM D877, kV(2) 35
Foam Test, ASTM D892, Seq. I, mL 10/0
FZG Scuffing Test, ASTM D5182
Failure Load Stage ---
Oxidation Stability
TOST, ASTM D943-04a, hours >5,000
Rust Test, ASTM D665 A&B Pass
Zinc, wt % 0.043
Licenses & Approvals

Megaflow AW Hydraulic Oil meets the requirements of the following industry and OEM specifications:

  • DIN 51524 Part 3, Antiwear Hydraulic Oils, Type HVLP
  • Eaton-Vickers I-286-S, M-2950-S
  • ISO 11158:1997, Family H (Hydraulic Systems), Type HV
  • Parker Hannifin (Denison) HF-0, HF-1, HF-2

Additional Details

ISO Grade 22
Specific Gravity @ 60°F 0.858
Density, lbs/gal @ 60°F 7.14
Color, ASTM D1500 0.5
Flash Point (COC), °C (°F) 193 (379)
Pour Point, °C (°F) -50 (-58)
Viscosity
cSt @ 40°C 22
cSt @ 100°C 4.7
SUS @ 100°F 106
SUS @ 210°F 40.6
Viscosity Index 136
Acid Number, ASTM D974, mg KOH/g 0.38
Copper Corrosion, ASTM D130 1a
Demulsibility, ASTM D1401, minutes to pass 15
Dielectric Strength, ASTM D877, kV(2) 35
Foam Test, ASTM D892, Seq. I, mL 0/0
FZG Scuffing Test, ASTM D5182
Failure Load Stage
Oxidation Stability
TOST, ASTM D943-04a, hours >5,000
Rust Test, ASTM D665 A&B Pass
Zinc, wt % 0.043
Licenses & Approvals

Megaflow AW Hydraulic Oil meets the requirements of the following industry and OEM specifications:

  • DIN 51524 Part 3, Antiwear Hydraulic Oils, Type HVLP
  • Eaton-Vickers I-286-S, M-2950-S
  • ISO 11158:1997, Family H (Hydraulic Systems), Type HV
  • Parker Hannifin (Denison) HF-0, HF-1, HF-2

Additional Details

ISO Grade 32
Specific Gravity @ 60°F 0.861
Density, lbs/gal @ 60°F 7.17
Color, ASTM D1500 0.5
Flash Point (COC), °C (°F) 204 (399)
Pour Point, °C (°F) -45 (-49)
Viscosity
cSt @ 40°C 32
cSt @ 100°C 6
SUS @ 100°F 150
SUS @ 210°F 45.9
Viscosity Index 136
Acid Number, ASTM D974, mg KOH/g 0.38
Copper Corrosion, ASTM D130 1a
Demulsibility, ASTM D1401, minutes to pass 15
Dielectric Strength, ASTM D877, kV(2) 35
Foam Test, ASTM D892, Seq. I, mL 0/0
FZG Scuffing Test, ASTM D5182
Failure Load Stage
Oxidation Stability
TOST, ASTM D943-04a, hours >5,000
Rust Test, ASTM D665 A&B Pass
Zinc, wt % 0.043
Licenses & Approvals

Megaflow AW Hydraulic Oil meets the requirements of the following industry and OEM specifications:

  • DIN 51524 Part 3, Antiwear Hydraulic Oils, Type HVLP
  • Eaton-Vickers I-286-S, M-2950-S
  • ISO 11158:1997, Family H (Hydraulic Systems), Type HV
  • Parker Hannifin (Denison) HF-0, HF-1, HF-2

Additional Details

ISO Grade 46
Specific Gravity @ 60°F 0.868
Density, lbs/gal @ 60°F 7.23
Color, ASTM D1500 0.5
Flash Point (COC), °C (°F) 213 (415)
Pour Point, °C (°F) -45 (-49)
Viscosity
cSt @ 40°C 46
cSt @ 100°C 7.7
SUS @ 100°F 214
SUS @ 210°F 51.5
Viscosity Index 135
Acid Number, ASTM D974, mg KOH/g 0.38
Copper Corrosion, ASTM D130 1a
Demulsibility, ASTM D1401, minutes to pass 15
Dielectric Strength, ASTM D877, kV(2) 35
Foam Test, ASTM D892, Seq. I, mL 0/0
FZG Scuffing Test, ASTM D5182
Failure Load Stage 12
Oxidation Stability
TOST, ASTM D943-04a, hours >5,000
Rust Test, ASTM D665 A&B Pass
Zinc, wt % 0.043
Licenses & Approvals

Megaflow AW Hydraulic Oil meets the requirements of the following industry and OEM specifications:

  • DIN 51524 Part 3, Antiwear Hydraulic Oils, Type HVLP
  • Eaton-Vickers I-286-S, M-2950-S
  • ISO 11158:1997, Family H (Hydraulic Systems), Type HV
  • Parker Hannifin (Denison) HF-0, HF-1, HF-2

Additional Details

ISO Grade 68
Specific Gravity @ 60°F 0.874
Density, lbs/gal @ 60°F 7.28
Color, ASTM D1500 0.5
Flash Point (COC), °C (°F) 218 (425)
Pour Point, °C (°F) -42 (-44)
Viscosity
cSt @ 40°C 68
cSt @ 100°C 10.2
SUS @ 100°F 315
SUS @ 210°F 60
Viscosity Index 135
Acid Number, ASTM D974, mg KOH/g 0.38
Copper Corrosion, ASTM D130 1a
Demulsibility, ASTM D1401, minutes to pass 15
Dielectric Strength, ASTM D877, kV(2) 35
Foam Test, ASTM D892, Seq. I, mL 0/0
FZG Scuffing Test, ASTM D5182
Failure Load Stage 12
Oxidation Stability
TOST, ASTM D943-04a, hours >5,000
Rust Test, ASTM D665 A&B Pass
Zinc, wt % 0.043
Licenses & Approvals

Megaflow AW Hydraulic Oil meets the requirements of the following industry and OEM specifications:

  • DIN 51524 Part 3, Antiwear Hydraulic Oils, Type HVLP
  • Eaton-Vickers I-286-S, M-2950-S
  • ISO 11158:1997, Family H (Hydraulic Systems), Type HV
  • Parker Hannifin (Denison) HF-0, HF-1, HF-2

Additional Details

ISO Grade 100
Specific Gravity @ 60°F 0.878
Density, lbs/gal @ 60°F 7.31
Color, ASTM D1500 0.5
Flash Point (COC), °C (°F) 218 (425)
Pour Point, °C (°F) -42 (-44)
Viscosity
cSt @ 40°C 100
cSt @ 100°C 13.5
SUS @ 100°F 463
SUS @ 210°F 72.2
Viscosity Index 135
Acid Number, ASTM D974, mg KOH/g 0.38
Copper Corrosion, ASTM D130 1a
Demulsibility, ASTM D1401, minutes to pass 15
Dielectric Strength, ASTM D877, kV(2) 35
Foam Test, ASTM D892, Seq. I, mL 0/0
FZG Scuffing Test, ASTM D5182
Failure Load Stage 12
Oxidation Stability
TOST, ASTM D943-04a, hours >5,000
Rust Test, ASTM D665 A&B Pass
Zinc, wt % 0.043

Product Inquiry